<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-26 10-19-34
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 5/5, 57 dBuV VOLTAGE
Pilot RDS Phase Difference
6.4 kHz 3.9 kHz -9 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
10 kHz 71 kHz 10120 0,0000
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
5,9 dBr 6,95 dBr 8,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 10:19, 26.07.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 5/5 (57 dBuV) Max at: 71 kHz MIN: 10 kHz % above 75 kHz: 0,0000 Acquired: 2025/07/26 10:18:30 Total samples: 10120 Equivalent time: 0:08:26 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 8,1 dBr MIN: 5,9 dBr AVE: 6,95 dBr % above 10,2 dBr: 0,0 Last value: 7,5 dBr (2025/07/26 10:18:30) Station: 96.90 MHz, signal: 5/5 (56 dBuV) 10:12 10:13 10:14 10:15 10:16 10:17 10:18 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality